3-8 WANsuite 5260/5230
RAS
Sets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by
the terminal equipment when an improper signal is received from the facility
(or upon receipt of unframed all ones). The default is 0 seconds (Disabled).
Reset Timer
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset.
The Network screens provide the user-activated buttons described below.
CAUTION: Performance data will be lost upon power cycle or after performing a
Maintenance Reset/Restart.
Figure 3.5
Performance/Summary Screen
Button Function
Submit Sets any values that have been changed.
Clear Alarms Resets the alarm conditions and counts to zero.
Performance Displays a Performance/Summary screen that shows a current
count of the number of error events that have occurred over the
past 24 hours and the past 30 days.
Channels Displays the Channel Table Details Screen on page 3-21,
showing each channel by index number. Each channel’s rate
and service (by number) are displayed and can be changed
through user input.
Network 1 (or
Network 2)
Services
Displays the Services screen for the Network 1 or Network 2
interface.
Refresh Refreshes data on the current page.