Résumé du contenu

Page 1 - User Manual

Verilink QPRI 2921 User ManualSeptember 1999P/N 880-503143-001-A1

Page 2

x Verilink QPRI 2921 Configuration Menu (Timing Options) ...3-10ISDN PRI Configuration Menu ...

Page 3 - FCC Requirements

Verilink QPRI 2921 1-1Chapter1QPRI 2921 Dual-Port ISDN Primary Rate InterfaceThe QPRI 2921 application module working in conjunction with an NCM 2000

Page 4 - Lithium Battery

QPRI 2921 Dual-Port ISDN Primary Rate Interface1-2 Verilink QPRI 2921FeaturesThe QPRI 2921 system has the following features:T1 Digital Transmission F

Page 5 - Safety Precautions

QPRI 2921 Dual-Port ISDN Primary Rate InterfaceVerilink QPRI 2921 1-3Advanced Programmable ArchitectureAll QPRI system hardware and software component

Page 6 - Publications Staff

QPRI 2921 Dual-Port ISDN Primary Rate Interface1-4 Verilink QPRI 2921LEDsThe QPRI front panel’s System LED (SYS) is green when the module has passed t

Page 7

QPRI 2921 Dual-Port ISDN Primary Rate InterfaceVerilink QPRI 2921 1-5Figure 1-3 CIM Configurations NOTE:Equipment Ports 1 and 2 require adapter cable

Page 8 - viii Verilink QPRI 2921

QPRI 2921 Dual-Port ISDN Primary Rate Interface1-6 Verilink QPRI 2921Table 1-2 CIM Specifications Technical and Regulatory ComplianceThis product com

Page 9 - QPRI 2921

Verilink QPRI 2921 2-1Chapter2Quick Set-UpThis chapter provides step-by-step procedures as an example for setting up your QPRI 2921 module and creatin

Page 10

Quick Set-Up2-2 Verilink QPRI 2921When Information Required NotesBefore Ordering ISDNCheck for availability—Call or otherwise access your network serv

Page 11 - Rate Interface

Quick Set-UpVerilink QPRI 2921 2-3Getting StartedAfter the NCM and QPRI modules and their NIM/CIM have been installed in their appropriate shelf/slots

Page 13 - System Components

Quick Set-Up2-4 Verilink QPRI 2921Reconnect to the NCM Local port for further operations.Figure 2-2 NCM Main Menu -- VERILINK NCM CONTROLLER : FW Rev

Page 14 - Interface

Quick Set-UpVerilink QPRI 2921 2-5Network Port Configuration1. From the NCM ASCII interface Main Menu, Figure 2-2, select the QPRI application module

Page 15 - Specifications

Quick Set-Up2-6 Verilink QPRI 29217. Press B, then 1, ENTER, then 1 to select 0db as the line build out for Net Port 1. Press B, then 2, ENTER, then 1

Page 16

Quick Set-UpVerilink QPRI 2921 2-7For each port:2. Press S, then the port number, ENTER, to assign the FDL Standard to the port. Options available for

Page 17 - Quick Set-Up

Quick Set-Up2-8 Verilink QPRI 2921selecting T. When the R) R) R) R) “Receive clock from shelf” option has been selected to be YES, the Configuration

Page 18

Quick Set-UpVerilink QPRI 2921 2-9Figure 2-9 PRI Port Configuration Menu 2. Press I, then 1, ENTER, then Y to put Port 1 in service. Press I, then 2,

Page 19 - Getting Started

Quick Set-Up2-10 Verilink QPRI 2921 e. Select R) “reset card” to reboot the module and implement NFAS.NOTE:If you use ESF/B8ZS:Do not invert the D Ch

Page 20

Quick Set-UpVerilink QPRI 2921 2-11Figure 2-13 PRI Port 1 Add Call Profile Menu 2. R) Call Profile Ref—Select an identifying reference number that is

Page 21 - Network Port Configuration

Quick Set-Up2-12 Verilink QPRI 29216. I) Ext Numbering Plan—Ask your NSP for their external numbering plan. Your choices are “Unknown”, “ISDN-E.164”,

Page 22 - FDL Options

Quick Set-UpVerilink QPRI 2921 2-13Setting Alarm (Backup Trigger) ParametersWhen normal service is interrupted, errored, or lost, an alarm triggers th

Page 23 - Timing Options

Verilink QPRI 2921 Manualiii Copyright NoticeCopyright  1999 Verilink Corporation. All rights reserved.This document does not create any express or i

Page 24 - ISDN PRI Port Configuration

Quick Set-Up2-14 Verilink QPRI 2921Building CircuitsCircuit building is a primary function of the NCM 2000. For general information on circuit buildin

Page 25

Quick Set-UpVerilink QPRI 2921 2-15Figure 2-18 Circuit Manager Menu (With Circuits Added)Figure 2-19 Add Circuit MenuFigure 2-20 Circuit Manager Menu•

Page 26 - PRI Call Profile

Quick Set-Up2-16 Verilink QPRI 2921•Port providing backup is the Source port of the primary circuit.•Circuit type is “Primary” for the main circuit an

Page 27

Quick Set-UpVerilink QPRI 2921 2-17When Information Required NotesBefore Ordering ISDNCheck for availability—Call or otherwise access your network ser

Page 28 - 2-12 Verilink QPRI 2921

Quick Set-Up2-18 Verilink QPRI 2921

Page 29

Verilink QPRI 2921 3-1Chapter3Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceISDN AccessFor ISDN functionality, the QPRI 2921 Craft interfa

Page 30 - Building Circuits

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-2 Verilink QPRI 2921NOTE:Setting the password on the NCM has no effect on the passwords of

Page 31

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-3Figure 3-1 NCM Main Menu The node master is the module responsible for

Page 32 - 2-16 Verilink QPRI 2921

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-4 Verilink QPRI 2921Shelf and Slot ParametersTo access a QPRI module from the Main Menu, e

Page 33

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-5Administration MenuWhen the shelf/slot address for the QPRI 2921 is se

Page 34 - 2-18 Verilink QPRI 2921

ivVerilink QPRI 2921 User Manual• If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you w

Page 35 - NCM 2000 Craft Interface

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-6 Verilink QPRI 2921Configuration MenuTyping the command C from Main Menu displays the QPR

Page 36 - NCM Main Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-7Table 3-5T1 Port Configuration Menu CommandsCommand Description Option

Page 37

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-8 Verilink QPRI 2921NDnNetwork Density: Use this option to specify the type of network den

Page 38 - Shelf and Slot Parameters

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-9When finished configuring the T1 network ports, enter X until you retu

Page 39 - Administration Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-10 Verilink QPRI 2921ConfigurationMenu (TimingOptions)To access the Configuration Menu (Ti

Page 40 - Configuration Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-11For ISDN, you must provide shelf timing derived from the ISDN PRI spa

Page 41

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-12 Verilink QPRI 2921If you enable “Receive Clock from Shelf” (which is what you should do

Page 42

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-13Recommended settings for timing when the QPRI 2921 is being used for

Page 43 - FDL Configuration

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-14 Verilink QPRI 2921Figure 3-9 PRI Port Configuration Menu Table 3-10PRI Port Configurati

Page 44 - Options)

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-15PRI Call ProfileConfigurationMenuAn ISDN Call Profile defines the net

Page 45

Verilink QPRI 2921 Manualv DeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität benu

Page 46 - Option selected is YES

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-16 Verilink QPRI 2921Port n PRI CallProfileConfigurationMenuFrom the PRI Call Profile Conf

Page 47 - PRI Port

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-17•Extension Number of Digits•Extension Call NumberNOTE:Acceptance of t

Page 48

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-18 Verilink QPRI 2921PRI Performance /Statistics MenuTo access the PRI Performance/Statist

Page 49

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-19Figure 3-13 PRI Performance/Statistics Menu Table 3-14PRI Performance

Page 50

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-20 Verilink QPRI 2921Figure 3-14 Port 1 PRI 15 Minute Performance DataWhen the options pre

Page 51

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-21Figure 3-16 Diagnostics MenuNOTE:If the loopback does not activate, u

Page 52 - Statistics Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-22 Verilink QPRI 2921When finished configuring the T1 port diagnostics parameters, enter X

Page 53

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-23NOTE:To do an LLB BOP or a PLB BOP to the far-end, set the far-end “N

Page 54 - Diagnostics Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-24 Verilink QPRI 2921Table 3-16Performance/Status Menu Commands.Performance / Status Menu

Page 55

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-25Figure 3-18 Performance/Status Menu (24hr T1 Performance Data Summary

Page 56

viVerilink QPRI 2921 User Manual• This product should be operated only from the type of power source indicated on the marking label and manual. If you

Page 57 - Performance / Status Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-26 Verilink QPRI 2921When one of these options is selected, the previous 24 hour data is d

Page 58 - Data Summary)

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-27Figure 3-19 Net Port Alarm Threshold Status MenuCounter MenuEnter C f

Page 59

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-28 Verilink QPRI 2921Net Port Alarm MenuTo access the Net Port Alarm Menu, enter A from th

Page 60 - Threshold Status

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-29For example, if the LOF interval is set to 100 seconds, and the LOF t

Page 61 - Counter Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-30 Verilink QPRI 2921Table 3-20Net Port Alarm Threshold Configuration Menu CommandsCommand

Page 62 - Net Port Alarm Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-31Net Port Alarm Theshold Status MenuTo display the Net Port Alarm Thre

Page 63

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-32 Verilink QPRI 2921Figure 3-23 Net Port Alarm Threshold StatusCircuit Manager MenuTo acc

Page 64

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-33The port line code selection (for example, 56k or 64k circuits) can l

Page 65 - Theshold Status

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-34 Verilink QPRI 2921Add Circuit SubmenuUse this option to create a new circuit. Specify t

Page 66 - Circuit Manager Menu

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-35Table 3-22Add Circuit Submenu CommandsCommand Description OptionsNNam

Page 67

Verilink QPRI 2921 viiWhen Information Required NotesBefore Ordering ISDNCheck for availability—Call or otherwise access your network service provide

Page 68 - Add Circuit

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-36 Verilink QPRI 2921Search Circuit SubmenuUse this option to search for or list existing

Page 69

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-37Edit Circuit SubmenuTo change a circuit’s characteristics, use the Ed

Page 70 - Delete Circuit

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-38 Verilink QPRI 2921DPDestination Port—Displays the Node “Map” and prompts for the DEST P

Page 71 - Edit Circuit

Configuring the QPRI 2921 Via the NCM 2000 Craft InterfaceVerilink QPRI 2921 3-39Manufacturing InfoTo display the firmware versions and CIM types, cho

Page 72

Configuring the QPRI 2921 Via the NCM 2000 Craft Interface3-40 Verilink QPRI 2921

Page 73 - System Log Off

Verilink QPRI 2921 4-1Chapter4TroubleshootingController card(s) poll the various modules for alarms. If alarm reporting is enabled for the node and fo

Page 74 - 3-40 Verilink QPRI 2921

Troubleshooting4-2 Verilink QPRI 2921Status CodeThe status code column displays a decimal code when using an ASCII terminal. (Varies depending on SNMP

Page 75 - Troubleshooting

TroubleshootingVerilink QPRI 2921 4-3What To Do About AlarmsSome alarms clear after the user-configured timeout has expired. Other alarms require corr

Page 76 - 4-2 Verilink QPRI 2921

Troubleshooting4-4 Verilink QPRI 2921Alarm ListFault conditions can result in critical, major, or minor alarms. In addition, a fault condition can als

Page 77 - What To Do About Alarms

TroubleshootingVerilink QPRI 2921 4-5Loss of Frame Alignment (E1 Only)This condition occurs when three consecutive in-error frame alignment signals (w

Page 78 - Alarm List

viii Verilink QPRI 2921

Page 79

Troubleshooting4-6 Verilink QPRI 2921Interpreting Front Panel LEDsThe LED indicators on the front panel of the QPRI 2921 module display errors caused

Page 80 - Interpreting Front Panel LEDs

TroubleshootingVerilink QPRI 2921 4-7System LEDThe System LED displays node controller assignments and node communication conditions.Table 4-3 System

Page 81 - System LED

Troubleshooting4-8 Verilink QPRI 2921

Page 82 - 4-8 Verilink QPRI 2921

IndexVerilink QPRI 2921 Index-1Numerics1/8test pattern 3-222N1 5-1test pattern 3-222N20-1test pattern 3-223 in 24 3-2255 Octettest pattern 3-22Aadd ci

Page 83

Index-2 Verilink QPRI 2921LLEDsfront panel 4-6Line Loopback 3-21list circuits 3-33LLB 3-21LLB BOP 3-22Local Loopback 3-21LOF 3-25, 3-28, 3-30loopbacks