Verilink REMS Rel. Note (883-101598-001) Product Manual Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel informatique Verilink REMS Rel. Note (883-101598-001) Product Manual. Verilink REMS Rel. Note (883-101598-001) Product Manual User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Part Number 883-101598-001-A Red Zone Encryption Management System (REMS) Release Notes 1
Release
Notes
Access System 2000
Red Zone Encryption Management
System (REMS)
Release Notes
Read this Release Notes document before you read the REMS user
manual.
This Release Notes provides corrected information for the Red Zone
Encryption Management System User Manual, Chapter 6, Configuring
and starting REMS, in the section, “Configuring REMS using the
thumbwheel switches. Use the following information instead of section
mentioned above.
Verilink suggests you manually cross out that section in the A(1) rev of
the REMS user manual, up to but not including the section, “Interpreting
the LED indicators, page 6-5.”)
Configuring REMS using the thumbwheel switch
The operator uses the EXE (execute) and FUNCTION thumbwheel
switches on the NCC 2020 modules to configure REMS. There are
thumbwheel switches in both the FBR and the BRC. You must configure
the FBR and the BRC separately, as if they were two separate AS2000
nodes.
Figur e1, NCC Thumbwheel Switches shows the top section of the master
NCC 2020 front panel.
!
IMPORTANT
TIP
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - System (REMS)

Part Number 883-101598-001-A Red Zone Encryption Management System (REMS) Release Notes 1ReleaseNotesAccess System 2000Red Zone Encryption Management

Page 2 - Using the

Access System 2000 Red Zone Encryption Management System (REMS) Release Notes2Red Zone Encryption Management System (REMS) Release Notes Part Number 8

Page 3 - 2020 using the

Configuring REMS using the thumbwheel switchPart Number 883-101598-001-A Red Zone Encryption Management System (REMS) Release Notes 3Each command cons

Page 4 - Procedure for

Access System 2000 Red Zone Encryption Management System (REMS) Release Notes4Red Zone Encryption Management System (REMS) Release Notes Part Number 8

Page 5

Configuring REMS using the thumbwheel switchPart Number 883-101598-001-A Red Zone Encryption Management System (REMS) Release Notes 5FBR Thumbwheel Co

Page 6 - Release Notes

Access System 2000 Red Zone Encryption Management System (REMS) Release Notes6Red Zone Encryption Management System (REMS) Release Notes Part Number 8

Commentaires sur ces manuels

Pas de commentaire