Verilink DPRI 2922 (880-503142-001) Product Manual Manuel d'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 91
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
Quick Set-Up
2-10
Verilink DPRI 2922
2. Set the Switch Type, Own Numbering Plan, and Own
Numbering Type according to the parameters your NSP has
provided you (use the checksheet provided). The choices
shown above are a possible (and recommended) configuration.
3. Set the Security Level according to your particular needs.
4. Set the
L2
auto establish to “Yes”. It allows for verification of
signal connection.
Setting Alarm (Backup Trigger) Parameters
When normal T1 service is interrupted, errored, or lost, an alarm
triggers the backup circuit. Therefore, this alarm must be set for
the T1/Data Ports you want to monitor/trigger for backup
activation.
1. Select
A
from the
Main Menu
, Figure 2-1, to access the
Net
Port Alarm Menu
.
2. Set the “Card Alarm Reporting” option (
A
) to
YES
.
Figure 2-9 Net Port Alarm Menu
3. Select
C
to configure thresholds.
A [127.255.255.0] [1,2] DIDCSU 2912 > a
-- DIDCSU 2912 NET PORT ALARM MENU --
N) NMS Address 128.0.0.0
A) Card Alarm Reporting YES
C) Configure Thresholds S) Alarm status
O) Display Alarm Buffer Tn) Set Default Thresholds
X) exit this screen
A [127.255.255.0] [1,2] DIDCSU 2912 >
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 90 91

Commentaires sur ces manuels

Pas de commentaire