Quick Set-Up
Verilink DPRI 2922
2-7
Figure 2-5 Configuration Menu (Timing Options)
2. All primary and dial-backup circuits must use shelf timing to
synchronize with each other; therefore, select
R
, then
YES
,
then refresh the screen by exiting to the
T1 Port
Configuration Menu
and then returning to the screen by
selecting
T
. When the
R)
R) R)
R)
“Receive clock from shelf” option has
been selected to be
YES
, the
Configuration Menu (Timing
Options)
menu displays as shown in Figure 2-4.
3. Use the ISDN network ports as the primary and secondary
sources. Use
INTERNAL
as the tertiary source. For example, if
the DIDCSU 2912 is in slot 2, the shelf timing table should look
like Figure 2-4. Exit to the
Configuration Menu
.
NOTE: Ensure that the card used as a timing source is set to Receive Clock
From Shelf as well.
Data Port Configuration
After both the DIDCSU module network ports have been properly
configured, continue with the data port configuration. You need to
know the types of equipment that will be connected to your data
ports and the interfaces that they will need. Refer again to the
filled-out checklists and worksheets.
1. From the NCM ASCII interface
Main Menu
(with the DIDCSU
designated as the active card), select option
C
,
“Configuration”, to start the configuration task.
Figure 2-6 Configuration Menu
2. From the
Configuration Menu
, select option
D
to access the
Data Port Configuration Menu
.
-- DIDCSU 2912 CONFIGURATION MENU (TIMING OPTIONS)--
Current shelf timing source: Card 2, INTERNAL (PRIMARY)
Source Slot Number Synchronization Auto Restore
PRIMARY PC) 2 PS) NET1 PA) YES
SECONDARY SC) 2 SS) NET2 SA) YES
TERTIARY TC) 2 TS) INTERNAL TA) YES
R) Receive clock from shelf: YES
X) exit this screen
A [127.255.255.0] [1,2] DIDCSU 2912 >
A [127.255.255.0] [1,2] DIDCSU 2912 > c
-- DIDCSU 2912 CONFIGURATION MENU --
P) T1 port D) data port
I) ISDN PRI X) exit this screen
A [127.255.255.0] [1,2] DIDCSU 2912 >