Verilink IMUX User ManualSeptember 1999P/N 880-503137-001-B1
Overview1-2 Verilink IMUX User ManualApplicationsThe IMUX can be used with multiple AS3000 application modules. When the IMUX is combined with a QUAD
OverviewVerilink IMUX User Manual 1-3IMUX FeaturesThis section provides information on the features of the IMUX.Data RatesThe Inverse Multiplexer has
Overview1-4 Verilink IMUX User ManualTable 1-2 Rear Connector Modules for IMUX Figure 1-2 IMUX Front Panel with DIM Rear Panels IMUX Compliancy Standa
OverviewVerilink IMUX User Manual 1-5Agency ApprovalsThis product is certified by the following agencies who verify compliance with regulatory require
Overview1-6 Verilink IMUX User Manual
Verilink IMUX User Manual 2-1Chapter2Quick Set-UpThe Quick Set-Up section provides the steps necessary to install and configure a typical IMUX configu
Quick Set-Up2-2 Verilink IMUX User ManualInstallationMount the shelf within an air-conditioned room on a standard 19” or 23” rack. Refer to the Access
Quick Set-UpVerilink IMUX User Manual 2-3NOTE:For the rest of this chapter, you will not be instructed to press ENTER after each command. Generally, E
Quick Set-Up2-4 Verilink IMUX User ManualIMUX Configuration MenuThe Configuration Menu is used to configure the data ports of the IMUX. From the IMUX
Quick Set-UpVerilink IMUX User Manual 2-52. Type the slot number of the second IMUX (in this example “8”).When the IMUX is selected, brackets ([ ]) a
iiVerilink IMUX User ManualCopyright NoticeCopyright 1999 Verilink Corporation. All rights reserved.This document does not create any express or imp
Quick Set-Up2-6 Verilink IMUX User ManualFigure 2-3 Example ConfigurationsNOTE:The assumption is made that the ports of the IMUX (slots 5 and 8), QUAD
Quick Set-UpVerilink IMUX User Manual 2-7Figure 2-4 Circuit Manager MenuWhen there are no circuits configured yet, the following message displays: &g
Quick Set-Up2-8 Verilink IMUX User Manual2. Use the M command to set the mode to 64k (option 1), this means that each DS0 timeslot used will use the f
Quick Set-UpVerilink IMUX User Manual 2-9NOTE:When the name of an active circuit is changed in the Edit Circuit Menu, a new circuit is created with th
Quick Set-Up2-10 Verilink IMUX User ManualM1-3 to IMUXThis example maps the M1-3 (slot 6), T1 number 9, 10, and 11, to the IMUX module in slot 5. From
Quick Set-UpVerilink IMUX User Manual 2-11“X’s” when the lines are operating. Check both IMUX Configuration Menus (slots 5 and 8) to ensure all lines
Quick Set-Up2-12 Verilink IMUX User ManualLine RestoralFor the previous circuit building examples, the M1-3 and QUAD T1 have an automatic line restora
Verilink IMUX User Manual 3-1Chapter3Configuration MenusThe IMUX menus are accessed from the System Controller Module (SCM). For detailed information
Configuration Menus3-2 Verilink IMUX User ManualFigure 3-1 IMUX Main MenuTable 3-1 IMUX Main MenuIMUX Configuration MenuTo configure the IMUX options,
Configuration MenusVerilink IMUX User Manual 3-3Figure 3-2 IMUX Configuration Menu OptionsTable 3-2 describes the IMUX Configuration Menu options and
Verilink IMUX User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you warn
Configuration Menus3-4 Verilink IMUX User ManualH X X DTE Type—Indicates which type of rear connector module (CIM) has been detected. This field can d
Configuration MenusVerilink IMUX User Manual 3-5 Table 3-3 defines the status field (lower portion) of the IMUX Configuration Menu.Table 3-3 Status Fi
Configuration Menus3-6 Verilink IMUX User ManualAdministration MenuThe commands on the IMUX Administration Menu generate prompts designed to be self-e
Verilink IMUX User Manual 4-1Chapter4Performance MonitoringThis chapter provides information about IMUX performance monitoring, and includes the follo
Performance Monitoring4-2 Verilink IMUX User ManualAlarm MenuTo access the Alarm Menu from the IMUX Main Menu, type “A” and press ENTER. There are two
Performance MonitoringVerilink IMUX User Manual 4-3IMUX Performance MonitoringTo view the performance and status information for the IMUX, type “P” fr
Performance Monitoring4-4 Verilink IMUX User ManualTable 4-3 IMUX Performance/Status MenuThe Performance/Status Menu customizes to reflect the data po
Performance MonitoringVerilink IMUX User Manual 4-5The Loopback A and Loopback B signals are DTE signal lines used to request loopback operation as de
Performance Monitoring4-6 Verilink IMUX User Manual
Verilink IMUX User Manual 5-1Chapter5DiagnosticsThis chapter contains information about the IMUX diagnostics. The Diagnostics Menu is designed to aid
ivVerilink IMUX User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität benu
Diagnostics5-2 Verilink IMUX User ManualFigure 5-2 IMUX Diagnostic Menu - HSSIThe status fields are identical to the IMUX Performance/Status Menu fiel
DiagnosticsVerilink IMUX User Manual 5-3Figure 5-3 IMUX LoopbacksTable 5-2 IMUX LoopbacksLoopback Type DefinitionPayload Loopback (PLB) A PLB loops th
Diagnostics5-4 Verilink IMUX User Manual
Verilink IMUX User Manual A-1AppendixADefault ConfigurationThis appendix contains the default values for the IMUX. The Configuration Menu for the IMUX
Default ConfigurationA-2 Verilink IMUX User ManualPerformance MenuThe Performance Menu contains two defaults:•AIS Pattern—Disabled•Loopback—NoneFigure
IndexVerilink IMUX User Manual Index-1AAdding a Circuit 2-7AIS pattern 4-4, 5-2Alarm Indication Signal 4-4, 5-2Alarm Menu 4-2alarm transmission 5-1AS
Index-2 Verilink IMUX User Manual
VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546September 1999P/N 880-503137-001-B1
Verilink IMUX User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you are
viVerilink IMUX User Manual
IMUX User Manual Table of ContentsVerilink IMUX User Manual vOverview...
vi Verilink IMUX User ManualConfiguration Menu Defaults ..... Appendix-1Performance Menu ..
Verilink IMUX User Manual 1-1Chapter1OverviewThis manual describes Verilink’s Access System 3000 DS3 Inverse Multiplexer (IMUX) system. It is assumed
Commentaires sur ces manuels