Verilink WANsuite 5165 (34-00301.H) Product Manual Manuel d'utilisateur Page 47

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 235
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 46
Web Server Interface 3-17
Figure 3.13
Unit Access Details
Supervisory Screen
The Supervisory screen (Figure 3.14) displays the current speed of the
Supervisory port interface and other parameters described below.
Figure 3.14
Supervisory Screen
Speed
Changes the Supervisory port speed (in bits per second).
Values: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Default: 19200
Character Size
Selects the number of bits required to make up one asynchronous character.
Values: Five, Six, Seven, Eight
Default: Eight
Diagnostic Messages
Enables the Supervisory port to send out diagnostic messages upon power-up.
Values: Enable, Disable
Default: Enable
NOTICE: When in SCADA mode, these diagnostic messages disrupt the connected
device. Therefore, if using the SCADA mode, set this value to
“Disable.”
NOTICE: Diagnostic Messages must be set to “Enable” for the Verilink
Configuration Wizard to work.
Vue de la page 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 234 235

Commentaires sur ces manuels

Pas de commentaire