Configuration
Factory default settings are
underlined
.
Switch 1
Switch 2
Switch 3*
Switch 4
Switch S4 sets the unit address.
When using the 4051 with an
8100A Site Controller, each ele-
ment in a group must have a
unique unit address. As many as
50 units (with addresses from 1 to
50) can exist in a group. If the unit
is not connected to a site control-
ler, the NMS unit address should
be left at the factory default setting
of 1
where Position 1 is Up and all
other positions are Down.
Switch S4 has eight positions used
to create an 8-bit binary code for
an address in the range of 1 to 50.
Switch position S4-1 is the least
significant bit (LSB) and S4-8 is
the most significant bit (MSB). If a
switch is down, its value is 0. If
up, its value is that of the upper lo-
cation. The values are additive. For
example, to set a unit address to 5,
position S4-3 (binary value is 4)
and position S4-1 (binary value is
1) would be set Up for a unit ad-
dress of 5 (4+1). All other posi-
tions would be set Down.
Boot from S1-1
DIP switches
Down
Saved Configuration Up
DDS Mode S1-2
DDS II (64 kbps)
Down
DDS I (56 kbps) Up
Timing Source S1-3 S1-4
Network
Down Down
Internal Down Up
DTE Up Down
RTS/
CTS
Delay
DTE
Rate
Delay S1-5
Normal
56 kbps 0.4±0.02 ms Down
64 kbps 0.3±0.015 ms
Long 56 kbps 0.8±0.04 ms Up
64 kbps 0.6±0.03 ms
RTS, CTS, and
DCD Handshake
S1-6
Force True
Down
Normal Up
LL and RL S1-7
Disable
Down
Enable Up
DTE Alarm S1-8
Disable
Down
Enable Up
Antistream Timer S2-1
Off Down
30 seconds Up
V.54 Loop Detection S2-2
Enable
Down
Disable Up
Circuit Assurance S2-3
Enable Up
Disable
Down
Loop Mode S2-4
Bidirectional
Down
Unidirectional Up
SUPV Port Rate S2-5 S2-6
19.2 kbps
Down Down
1.2 kbps Down Up
2.4 kbps Up Down
9.6 kbps Up Up
NMS Port Rate S2-7 S2-8
19.2 kbps
Down Down
1.2 kbps Down Up
2.4 kbps Up Down
9.6 kbps Up Up
Force Download Mode S3-8
Normal Operation
Down
Begin Flash Download Up
* Switches S3-1 through S3-7
are not used.
7654321 8
LSB MSBbinary values
Down Up
1 2 4 8 16 32 64 128
00000000
145 Baytech Drive
San Jose, California 95134
127 Jetplex Circle
Madison, Alabama 35758
(800) 837-4546
www.verilink.com
FAX-On-Demand
(800) 957-5465
Technical Assistance Center
(800) 285-2755
Connections
1051-2 Rear Panel Pinouts
Pin T1 NET DDS NET*
TB1
Network/Clock
TB2
Alarm/Power
1 Data In Data Out Network In 48-V Return
2 Data In Data Out Network In Signal Ground
3 Not Used Not Used Network Out 48 VDC
4 Data Out Not Used Network Out Frame Ground
5 Data Out Not Used Station Clock Alarm Contact
6 Not Used Not Used Station Clock Common
7 Not Used Data In N/A N/A
8 Not Used Data In N/A N/A
* T1 NET connector converts to DDS NET using a supplied DDS
adapter cable (part number 9-1001-075-1).
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Switch 1 Switch 2 Switch 3 Switch 4
Down Up
Top-Edge View of the PRISM 4051
T1 DTE
123456789101112
( B )
NMS
IN
( B )
NMS
OUT
12
HIGH SPEED DTE
11 10 9 8 7 6 5 4 3 2 1
T1 NET
TB1 TB2
ENET
( A )
NMS
IN
( A )
NMS
OUT
TB1 TB2
Rear Panel of the Verilink 1051-2 Chassis
123456789101112
Vue de la page 1
1 2

Commentaires sur ces manuels

Pas de commentaire