T
OP
-E
DGE
V
IEW
OF
THE
PRISM 3021
Factory default settings are underlined.
Rear Panel Connections
Pin
E1 NET
(labeled
T1 NET)
NMS IN
NMS
OUT
TB1
Network/
Clock
TB2
Alarm/
Power
E1 DTE
(labeled T1
DTE)
1 Data In Not Used Not Used Ntwk In 48-V Return Tip Output
2 Data In Signal Gnd Signal Gnd Ntwk In Signal Gnd Ring Output
3 Not Used Data Out Data Out Ntwk Out -48 VDC Not Used
4 Data Out Data In Not Used Ntwk Out Frame Gnd Tip Input
5 Data Out Signal Gnd Signal Gnd Station Clk Alm Contact Ring Input
6 Not Used Not Used Not Used Station Clk Common Not Used
7 Not Used N/A N/A N/A N/A Chassis Gnd
8 Not Used N/A N/A N/A N/A Chassis Gnd
*
B
OTTOM
-E
DGE
V
IEW
OF
THE
PRISM 3021
Switch S1
81234567
E1-DTE Option Switch S1
18765432
Switch SW1
0
1
2
3
4
5
6
7
8
9
Switch S1
S1-1:
Sets network framing.
Down: CAS
Up: CCS
S1-2:
Sets CRC4.
Down: Enabled
Up: Disabled
S1-3:
Selects network line code.
Down: HDB3
Up: AMI
S1-4
and
S1-5:
Select the unit’s timing
source.
S1-6:
Selects keep alive framed and
unframed ones.
Down: Keep alive unframed ones
Up: Keep alive framed ones
S1-7:
Selects normal or inverted data
mode.
Down: Normal
Up: Inverted
S1-8:
Used for programming the Flash
memory.
Down: Disabled
Up: Enabled
Timing Source S1-4 S1-5
Network
Down Down
Internal Down Up
E1 DTE Up Down
DTE or External Up Up
Switch S2
Switch S2 sets the unit address. When using the
3021 with an 8100A Site Controller, each ele-
ment in a group must have a unique unit
address. As many as 50 units (with addresses
from 1 to 50) can exist in a group. If the unit is
not connected to a site controller, the NMS unit
address should be left at the factory default set-
ting of 1
where Position 1 is Up and all other
positions are Down.
Switch S2 has eight positions used to create an
8-bit binary code for an address in the range of
1 to 50. Switch position S2 -1 is the least signif-
icant bit (LSB) and S2-8 is the most significant
bit (MSB). If a switch is down, its value is 0. If
up, its value is that of the upper location. The
values are additive. For example, to set a unit
address to 5, position S2-3 (binary value is 4)
and position S2-1 (binary value is 1) would be
set
Up
for a unit address of 5 (4+1). All other
positions would be set
Down
.
7654321 8
LSB MSB
binary values
Down Up
1 2 4 8 16 32 64 128
00000000
Switch S2
81234567
Switch S3
81234567
Switch
S4
12345
Switch S3
S3-1
and
S3-2:
Set the NMS
port rate. Configure the port
for 8 bits, no parity, and 1
stop bit.
S3-3
and
S3-4:
Set the SUPV
port rate. Configure the port
for 8 bits, no parity, and 1
stop bit.
S3-5
and
S3-6:
Set the boot mode.
S3-7:
Selects the DTE rate
multiplier.
Down: N
×
64
Up: N
×
56
S3-8:
Selects the channel
assignment mode.
Down: Contiguous
Up: Alternating
NMS
Port Rate
S3-1 S3-2
19200 bps
Down Down
9600 bps Down Up
2400 bps Up Down
1200 bps Up Up
SUPV
Port Rate
S3-3 S3-4
38400 bps
Down Down
19200 bps Down Up
9600 bps Up Down
2400 bps Up Up
Boot
Mode
S3-5 S3-6
Switches
Down Down
RAM Down Up
ROM Up Down
Reserved
for future
expansion.
Up Up
Switch SW1
SW1:
Sets the national bit.
National Bit Switch Position
None 0
SA4
1
SA5 2
SA6 3
SA7 4
SA8 5
None 6-9
Switch S4
S4-1
through
S4-5:
Set the DTE rate.
DTE
Rate
N
×
56
(kbps)
N
×
64
(kbps)
S4-1 S4-2 S4-3 S4-4 S4-5
N=31
1,2
1736 1984 Down Down Down Down Down
N=30
1
1680 1920 Up Down Down Down Down
N=29
1
1624 1856 Down Up Down Down Down
N=28
1
1568 1792 Up Up Down Down Down
N=27
1
1512 1728 Down Down Up Down Down
N=26
1
1456 1664 Up Down Up Down Down
N=25
1
1400 1600 Down Up Up Down Down
N=24
1
1344 1536 Up Up Up Down Down
N=23
1
1288 1472 Down Down Down Up Down
N=22
1
1232 1408 Up Down Down Up Down
N=21
1
1176 1344 Down Up Down Up Down
N=20
1
1120 1280 Up Up Down Up Down
N=19
1
1064 1216 Down Down Up Up Down
N=18
1
1008 1152 Up Down Up Up Down
N=17
1
952 1088 Down Up Up Up Down
N=16
1
896 1024 Up Up Up Up Down
N=15 840 960 Down Down Down Down Up
N=14 784 896 Up Down Down Down Up
N=13 728 832 Down Up Down Down Up
N=12 672 768 Up Up Down Down Up
N=11 616 704 Down Down Up Down Up
N=10 560 640 Up Down Up Down Up
N=9 504 576 Down Up Up Down Up
N=8 448 512 Up Up Up Down Up
N=7 392 448 Down Down Down Up Up
N=6 336 384 Up Down Down Up Up
N=5 280 320 Down Up Down Up Up
N=4 224 256 Up Up Down Up Up
N=3 168 192 Down Down Up Up Up
N=2 112 128 Up Down Up Up Up
N=1 56 64DownUpUpUpUp
1
This selection is not valid if the Channel Assignment is set to Alternating.
2
This selection is not valid for CAS mode.
127 Jetplex Circle
Madison, Alabama 35748
Sales and Marketing
800-926-0085
205-772-3770
info@txport.com
Returns and RMA
800-926-0085, ext. 2227
Technical Support
800-258-2755
205-772-3770
TRANSPORT
®
E1-DTE Option Switch S1
S1-1:
Sets CRC4.
Down: Enabled
Up: Disabled
S1-2:
Selects the E1-DTE line code.
Down: HBD3
Up: AMI
S1-8:
Selects the E1-DTE line termination.
Down: 75 ohm
Up: 120 ohm
T1 DTE
( B )
NMS
IN
( B )
NMS
OUT
HIGH SPEED DTE
T1 NET
TB1 TB2
ENET
( A )
NMS
IN
( A )
NMS
OUT
TB1 TB2
Rear Panel of the TxPORT 1051-2 Chassis
123456789101112
123456789101112
12 8 7 6 5 4 3 21011 1 9
For 3021 applications, read E1 in place of T1 on the rear of the 1051 chassis.
Commentaires sur ces manuels