For future reference, all DIP switches
are provided with upper and lower
boxes to check according to the par-
ticular user selection. Factory default
settings are shown underlined
.
Verilink 1051 Chassis Rear View
(V.35 version also available)
Pin T1 DTE T1 NET
1 Data Out Data In
2 Data Out Data In
3 Not used Not used
4 Data In Data Out
5 Data In Data Out
6 Not used Not used
7, 8 Signal Gnd Signal Gnd
Pin NMS In NMS Out
1 Not Used Not Used
2 Signal Gnd Signal Gnd
3 Data Out Data Out
4 Data In Not Used
5 Signal Gnd Signal Gnd
6 Not Used Not Used
Chassis Connections
T1 DTE
123456789101112
( B )
NMS
IN
( B )
NMS
OUT
12
High Speed DTE
11 10 9 8 7 6 5 4 3 2 1
T1 NET
TB1 TB2
ENET
( A )
NMS
IN
( A )
NMS
OUT
123456789101112
TB1 TB2
RightLeft
Keep Alive
Keep Alive
Test Mode
Test Code
Test Pattern
Zeros
Reserved
Keep Alive
Keep Alive
Test Mode
Test Code
Test Pattern
Zeros
7654321
All Ones
Unframed
BERT
B8ZS
Framed
15
Loop Back
Framed
Clear
AMI
Unframed
175
Switch S2 (front panel)
Switch S3
7654321
Dn Up
S3-1 S3-2 LBO Level
Dn
Dn 0 dB
Dn Up -7.5 dB
Up Dn -15.0 dB
Up Up -22.5 dB
Network LBO: Sets the output
signal level of transmitted data.
The telco should provide the
proper setting. If unsure of the
exact setting, set to 0 dB.
S3-3 S3-4 S3-5 Distance
Up
Up Dn 0'-133'
Dn Dn Up 134'-266'
Up Dn Up 267'-399'
Dn Up Up 400'-533'
Up Up Up 534'-655'
S3-7 During Remote Loop
Up
:AIS to DTE
Dn: Network data to DTE
DTE LBO: The transmit output
level is selectable according to
the cable length from the CSU
DTE port to the T1 equipment.
S3-6 Line Code
Up
: Line code transparent
Dn: DTE AMI –> NET B8ZS
7 Keep Alive: All Ones sends a consecutive sequence of all ones back to
the network. Loopback sends any signal coming from the network
back to the network.
6 Keep Alive: Unframed
transmits the Keep Alive signal without
framing. Framed adds framing information to the Keep Alive signal.
5 Test Mode: Clear
allows network access via test jacks to run bit error
tests (affects network test only). BERT allows the CSU to send a bit
error rate test pattern after the set signal (LOOP) is sent.
4 Test Code: B8ZS
allows the CSU to be transparent to a B8ZS code
coming from the network and sets the test signals to B8ZS. AMI shows
a BPV error for each event.
3 Test Pattern: Framed
indicates that the test signals (Set, Reset, and
BERT) are framed. ‘Unframed’ indicates the test signals are unframed.
2 Zeros: 15
allows 15 successive zeros from the DTE before the Keep
Alive mode is activated. 175 allows 175 zeros before activation.
1 Reserved.
Switch S2 Description
This three-pin jumper straps the
ACO alarm contact. Position jump-
er over pins 1 and 2 for normally
open operation (closes on alarm) or
over pins 2 and 3 for normally
closed operation (opens on alarm).
NO
NC
1
2
3
Alarm Relay
The optional ACO/alarm card monitors the
alarm indicators for an alarm active or an
alarm clear condition and provides closure
contact points on the rear panel. The corre-
sponding front panel LED lights when an
alarm condition is detected on the four dif-
ferent conditions shown below.
1) Network AIS (all ones)
2) Network LOS (all zeros)
3) Network BPVs
4) DTE ones density
Optional Alarm Card
Circuit Board View
7654321
2100
Switch S3
Alarm Relay
front
panel
Factory set -
TXKX
do not change
Optional Alarm Card
Black squares indicate direction
of factory default switch settings
Reserved
950 Explorer Blvd.
Huntsville, AL 35806
800-926-0085
Product Technical Support
(8 a.m. to 5 p.m. Central)
800-285-2755 or
256-327-2255
E-mail:
support@verilink.com
Online:
www.verilink.com
Commentaires sur ces manuels