Chassis Connections
Pin T1 DTE T1 NET
1 Data Out Data In
2 Data Out Data In
3 Not Used Not Used
4 Data In Data Out
5 Data In Data Out
6 Not Used Not Used
7, 8 Chassis Gnd Chassis Gnd
Pin NMS In NMS Out
1 Not Used Not Used
2 Signal Gnd Signal Gnd
3 Data Out Data Out
4 Data In Not Used
5 Signal Gnd Signal Gnd
6 Not Used Not Used
T1 DTE
123456789101112
( B )
NMS
IN
( B )
NMS
OUT
12
High Speed DTE
11 10 9 8 7 6 5 4 3 2 1
T1 NET
TB2
TB1
ENET
( A )
NMS
IN
( A )
NMS
OUT
TB1 TB2
TxPORT 1051 Chassis Rear View
(V.35 version also available)
Switch S3
18765432
NOTE: For future reference, all
DIP switches are provided with
upper and lower boxes to check
according to the particular user
selection. Factory default set-
tings are shown underlined
.
This 3-pin jumper straps the ACO alarm contact.
Move the jumper to the left for normally open
operation (closes on alarm) or to the right for
normally closed operation (opens on alarm).
8654321
Dn Up
7
NCNO
Network LBO: Sets the output signal
level of the transmitted data.
S3-1 S3-2 Line Build Out
Dn Dn 0 dB
Dn Up -7.5 dB
Up Dn -15.0 dB
Up Up -22.5 dB
DTE LBO: The output level of the
DTE interface should match the cable
length from the CSU DTE port to the
attached equipment.
S3-3 S3-4 S3-5 Distance
Dn Dn Dn 0 -110
Dn Dn Up 110-220
Dn Up Dn 220-330
Dn Up Up 330-440
Up Dn Dn 440-550
Up Dn Up 550-655
Up Up Dn > 655
Up Up Up Square
Clock: Sets the CSU’s timing source
for data transmitted toward both the
network and DTE.
S3-6 S3-7 S3-8 Source
Dn Dn Dn Normal
Up Dn Dn Internal
Up Up Dn Network
Up Up Up DTE
Circuit Board View
Configuration Switch S3
Alarm Relay Mode
Alarm
Relay
Switch S4
18765432
Switch S5
18765432
Switch S6
18765432910
S4-1: T1.403 PRM:
Down - enabled Up
- disabled
S4-2:
Audible Alarm (buzzer)
Down
- disabled Up - enabled
Dn Up
Dn Up
S4-3 S4-4 Boot Mode
Dn Dn Boot from Switches
Dn Up Boot from RAM
Up Dn Boot from Manager
Up Up Boot from ROM
S4-5 S4-6 SUPV Port Rate
Dn Dn 19200 bps
Dn Up 9600 bps
Up Dn 2400 bps
Up Up 1200 bps
S4-7 S4-8 NMS Port Rate
Dn Dn 19200 bps
Dn Up 9600 bps
Up Dn 2400 bps
Up Up 1200 bps
S5-1: Network Line Framing - matches the CSU to
the framing of the network line.
Down
- ESF Up - D4
S5-2: DTE Line Framing - Matches the CSU to the
framing of the DTE line.
Down
- ESF Up - D4
S5-3: Network Line Coding
Down - AMI Up
- B8ZS
S5-4: DTE Line Coding
Down - AMI Up
- B8ZS
S5-5: Network AIS - Sets the all ones signal sent
out to the network in a keep alive condition.
Down
- Unframed Up - Framed
S5-6: Network Keep Alive Mode - Selects the ac-
tion to occur on a DTE loss of signal.
Down
- Send AIS Up - Loop NET data in to
NET data out
S5-7: ESF CRC Mode - Regenerates the CRC
code or passes the CRC code through unchanged.
Down
- Regenerate Up - Pass
S5-8: ESF FDL Mode - Terminates the received
data link in the CSU or passes it through unchanged.
Down
- Terminate Up - Pass
MSB LSB
S6-1: Zero Suppression (ones density):
Down
- Enable Up - disable
S6-2: Maintenance Reset
Down
- Off Up - On
S6-3 to S6-10: The NMS address is defined
with this 8-bit binary code. The factory
default value is 1, which is S6-10 in the up
position and S6-3 through S6-9 down.
Dn Up
1
2
4
8
16
32
64
128
Configuration Switch S6
Configuration Switch S4
Configuration Switch S5
127 Jetplex Circle
Madison, Alabama 35758
Sales and Marketing
800-926-0085
205-772-3770
info@txport.com
Returns/RMA
800-926-0085, ext. 2227
Technical Support
800-285-2755
205-772-3770
support@txport.com
TRANSPORT
®
86543217
86543217
86543217910
123456789101112